Cables And Accessories Back

Transport Case
Transport up to 12 ADF slats or 6 ADF and 5 case type slats or 8 case type slats only. 10mm on all sides, aluminum valance & edges, plated corners and hardware. EVA foam interior.  Custom matching high-tech transport cases snugly hold either case type or rack mount slats, or a combination of both.

 

Always Test First

Test 12 circuits at a time.  Plug into your wired terminal slats to see OPEN circuits at a glance.    Connection not complete, no light.  Connection complete light.  Safe extremely low current can’t  fire matches.  Use one of your gender changers and test any of your cables for open circuits.  Terminals on front for testing individual matches.  Powered by a 9 volt battery mounted  to the outside of the back panel.

 

Array Test Fixture

Test 144 circuits at a time.  Plug into your cable at the end of a run of slats and cables.  Push the button, rotate the knob to test all slat addresses, one address per stop.  Great for testing in the field during display setups.

Water Proof Cable
All solder connections sealed to keep out moisture. Heavy 22 gauge Multi stranded with a heavy PVC jacket, stays flexible.  Burning material may blemish them but seldom burns through the jacket. Available in standard lengths of 10, 25, 50, 100 and 200 feet. Also available in custom lengths (see price sheet). All cables are 22 gauge multi stranded.  This is a must to deliver the current for multi location cues on a single cable run. These are not computer cables.

12 Volt Power Cable
For powering any of our firing systems. The version shown here has an alligator clip . This is also available the same but has a male cigarette lighter plug on the end. The other end of both has a dual banana plug.
 

A B C D Switchbox

Used with the 12 Que mini firing units to expand to 48 ques or with the 144 que Array Touch Fire to expand to 576 ques at the turn of a dial.

Y Splitter

Branch off from one connection in two directions. Plugs into any female
connector with a male plug, then plug two male cables into its’ two female connectors. Say one to fronts, one to the main body, one to finale…
Compatible with all our systems.
 

Map Light

Don’t fumble in the dark.

Fits any of our firing units power cord dual banana jacks.

Also fits the Computer Interface Module.

Shorting Safety Shunts
For safety sake these are plugged into every slat during electric match
connecting. All the internal connections are joined together to keep electrical
transients from inducing into wiring, just as all electric match is shipped
Gender Changers
Female to Female connectors. Join cable lengths together to reach out to slats. Getting close to devices avoids that labor intensive ‘scab wire’. Use any time a cable isn’t long enough.
PyroSpringPost Kits
All Stainless Steel. Spring free length is 1”, compresses at 3 pounds when .75”. Cup washers ‘dig into’ wire for sure connections that won’t pull out. If mounted on metal slats, insulation shoulder washers must be used (not included).

 

Home